Skip to main content
Peppers Heating & Air — HVAC in Covington, GA
Learning Center · How HVAC Works · Learn

SEER2, HSPF2 and AFUE Explained: What HVAC Efficiency Ratings Mean

By Peppers Heating & Air Published

Quick answer

SEER2 rates how efficiently an air conditioner or heat pump cools, HSPF2 rates how efficiently a heat pump heats, and AFUE is the share of a furnace's fuel that becomes heat in your home. Georgia is in DOE's Southeast region, where a new split central air conditioner under 45,000 Btu/h must reach at least 14.3 SEER2 and a split heat pump 14.3 SEER2 and 7.5 HSPF2. Higher ratings pay off only with a good installation.

Published · Reviewed

Part of our AC installation and replacement guides.

What do SEER2, HSPF2 and AFUE actually measure?

SEER2, HSPF2 and AFUE are the three federal efficiency ratings a Georgia homeowner sees when shopping for a new air conditioner, heat pump or gas furnace, and each one measures a different job. SEER2 (Seasonal Energy Efficiency Ratio 2) rates cooling: the cooling a system delivers over a typical cooling season divided by the electricity it uses. HSPF2 (Heating Seasonal Performance Factor 2) rates a heat pump's heating: total heat delivered over the heating season divided by the electricity consumed. AFUE (Annual Fuel Utilization Efficiency) rates a furnace: the share of the fuel's energy that actually reaches the house as heat.

For all three ratings, a higher number means a more efficient system. An air conditioner only carries a SEER2 rating (and its companion, EER2, which measures efficiency at a single hot-day condition). A heat pump carries both SEER2 and HSPF2, because it cools in summer and heats in winter. A gas furnace carries AFUE, and the air conditioner or heat pump paired with it carries its own cooling rating.

SEER2 tells you how efficiently a system cools, HSPF2 tells you how efficiently a heat pump heats, and AFUE tells you how much of a furnace's fuel becomes heat in your home.

Why did SEER become SEER2 in 2023?

SEER became SEER2 because the U.S. Department of Energy (DOE) changed the laboratory test. Starting January 1, 2023, efficiency ratings for central air conditioners and heat pumps must come from a newer test procedure (10 CFR 430, appendix M1). That procedure created the SEER2, EER2 and HSPF2 metrics and added higher external static pressure requirements for all units, meaning the test blower pushes air against more resistance, closer to what real ductwork imposes.

Because the test is tougher, the same piece of equipment scores a lower number under SEER2 than it did under the old SEER scale. Trane, for example, describes the Southeast minimum of 14.3 SEER2 for a split heat pump as equivalent to about 15 SEER on the old scale. That's why a 2026 quote showing "14.3" is not a step down from an older system labeled "14"; the two numbers come from different tests and can't be compared directly.

A SEER2 number is not a lower-quality SEER number; it is the result of a stricter test, so compare SEER2 only with SEER2.

What are the minimum efficiency ratings for a new system in Georgia?

Georgia sits in DOE's Southeast region, which has higher minimums for central air conditioners than the northern states. Under the federal standards in 10 CFR 430.32 for equipment manufactured on or after January 1, 2023, the Southeast region (which includes Georgia, Alabama, the Carolinas, Florida, Tennessee, Texas and other southern states) requires the following:

  • Split-system air conditioners under 45,000 Btu/h (roughly under a 3.75-ton system): at least 14.3 SEER2, plus an EER2 of at least 11.7 if the SEER2 is below 15.2, or 9.8 if it is 15.2 or higher.
  • Split-system air conditioners of 45,000 Btu/h or more: at least 13.8 SEER2, with an EER2 of 11.2 (below 15.2 SEER2) or 9.8 (15.2 SEER2 and higher).
  • Split-system heat pumps: at least 14.3 SEER2 and 7.5 HSPF2. Heat pump minimums are national, so they are the same in Georgia as anywhere else.

The regional air conditioner standard is tied to where the equipment is installed, so a split air conditioner installed in Covington, Monroe or Madison must meet the Southeast number, not the lower 13.4 SEER2 national baseline that applies in the North. These are minimums; many systems sold in Georgia are rated well above them.

In Georgia, a new split-system central air conditioner under 45,000 Btu/h must be rated at least 14.3 SEER2, and a new split heat pump must be at least 14.3 SEER2 and 7.5 HSPF2.

What does AFUE mean for a gas furnace, and is the minimum changing?

AFUE is a percentage: DOE explains that an AFUE rating measures the amount of heat actually delivered to the house compared with the amount of fuel supplied to the furnace. An 80% AFUE furnace turns about 80% of its gas energy into heat for the home, and the rest leaves through the vent. A 95% AFUE furnace is a condensing furnace that captures extra heat from its exhaust, which is why it vents through plastic pipe and drains condensate.

Today, the federal minimum for a standard non-weatherized gas furnace is 80% AFUE. DOE has finalized a rule raising that minimum to 95% AFUE for non-weatherized gas furnaces manufactured on or after December 18, 2028. As of November 2026, that rule is in legal and regulatory flux: in June 2026 the U.S. Supreme Court sent the furnace-standard case back to the D.C. Circuit for reconsideration, and DOE has published an industry petition asking to push the compliance date to 2030. Homeowners planning a furnace replacement should treat the 2028 date as the current rule but expect possible changes. ENERGY STAR's current furnace criteria call for 95% AFUE or higher for gas furnaces in the U.S. South.

The federal floor for a standard gas furnace is 80% AFUE today, and a finalized 95% AFUE standard for furnaces made from December 2028 is back before a federal appeals court, and gas industry groups have petitioned DOE to delay it.

Do higher ratings always mean lower bills in a Georgia home?

Higher ratings mean lower energy use only when the system is sized, installed and maintained to deliver its rated performance. A rating is earned in a lab; in a house, efficiency depends on correct refrigerant charge, adequate airflow, leak-free ductwork and a clean filter and coil. A high-SEER2 air conditioner connected to leaky, undersized ducts in a hot attic can perform closer to a basic system.

Middle Georgia's long, humid cooling season means cooling efficiency usually matters more to the annual bill than heating efficiency, so SEER2 deserves the most attention when choosing an air conditioner or heat pump. Winters are milder but still bring freezing nights, which is where a heat pump's HSPF2 rating, or a furnace's AFUE, earns its keep. Variable-speed and two-stage equipment often posts higher SEER2 numbers and also tends to run longer, gentler cycles that pull more moisture out of the air, a real comfort benefit in a humid climate.

A rating describes what a system can do; the installation, ductwork and maintenance decide what it actually does in your house.

How do you find the ratings on the equipment you already have?

The fastest way to find your current system's ratings is to record the model numbers from the nameplate on the outdoor unit and the indoor furnace or air handler, then look them up in the manufacturer's product literature. Equipment made before 2023 will show SEER and HSPF rather than SEER2 and HSPF2. Furnaces are often labeled with AFUE on the nameplate or in the installation manual, and the vent type is a quick clue: a furnace venting through PVC plastic pipe is almost always a condensing, 90%-plus AFUE model, while a metal flue usually indicates an 80% furnace or older.

Reading labels and model numbers is safe homeowner work. Opening panels, testing electrical components, checking refrigerant pressures or inspecting a gas burner is technician work. An AC inspection and testing visit can confirm whether an older system is still performing near its original rating.

Your system's model numbers are the key to its ratings, and reading a nameplate is the only part of this check a homeowner needs to do.

How do efficiency ratings fit into a repair-or-replace decision?

Efficiency ratings are one input in a repair-or-replace decision, alongside system age, the cost of the repair and the refrigerant the system uses. An older system rated well below today's Southeast minimum will use noticeably more electricity than a new one; how much that matters depends on how hard the system works each summer. Many older systems also use R-410A refrigerant, which new residential equipment no longer uses; our guide to the R-410A to R-454B refrigerant change explains what that means for repairs.

If you're weighing a heat pump against a furnace, it helps to understand how a heat pump heats your home through a Georgia winter before comparing HSPF2 and AFUE side by side.

A large efficiency gap between your current system and today's minimums is a reason to price replacement, not a reason to replace on its own.

Frequently asked questions

Is 14.3 SEER2 the same as 14.3 SEER?

No. SEER2 comes from a stricter DOE test that began January 1, 2023, so the same equipment scores lower on SEER2 than on the old SEER scale; Trane describes 14.3 SEER2 as roughly equivalent to 15 SEER.

What is the minimum SEER2 for a new air conditioner in Georgia?

Georgia is in DOE's Southeast region, where a split-system central air conditioner under 45,000 Btu/h must be rated at least 14.3 SEER2, and a split system of 45,000 Btu/h or more must be at least 13.8 SEER2, each with a matching EER2 minimum.

What is a good HSPF2 rating for a heat pump in Georgia?

The federal minimum for a split-system heat pump is 7.5 HSPF2 nationwide; any rating above that heats more efficiently, and the right target depends on the home, the ductwork and how much heating it needs.

Do I have to replace my 80% AFUE furnace?

No. Efficiency standards apply to newly manufactured equipment, not to furnaces already installed and working; the finalized 95% AFUE standard applies to furnaces made on or after December 18, 2028, and that date could still change while the court case and an industry petition to delay it are pending.

Does a higher SEER2 rating guarantee lower electric bills?

No. A higher SEER2 rating means the equipment is capable of using less electricity, but real savings depend on correct sizing, refrigerant charge, airflow, duct condition and regular maintenance.

What is EER2 and why does it matter in the Southeast?

EER2 measures cooling efficiency at a single hot-weather test condition, and DOE requires split air conditioners installed in the Southeast to meet an EER2 minimum in addition to SEER2, which reflects the region's hot summers.

Sources

Talk to a technician

Get a straight answer about your system.

Tell us what's going on and our Covington team will get back to you during office hours (Mon–Fri 8–5, Sat 9–2).

Call our Covington office(770) 483-1282
  • Mon–Fri 8–5 · Sat 9–2
  • Repaired right the first time
  • 100% satisfaction guaranteed
  • Trane Customer Care Dealer

4109 Robinson St NW, Covington, GA 30014

Fast response

Request your service

No obligation. We never sell your info.

Request Service

Loading form. If it does not load, please use the other contact options on this page.

By submitting, you agree to our Privacy Policy and Terms. If you opt in to texts, message & data rates may apply and you can reply STOP to opt out.